Products

Products

380V Rack Mount Static Var Generator
  • 380V Rack Mount Static Var Generator380V Rack Mount Static Var Generator
  • 380V Rack Mount Static Var Generator380V Rack Mount Static Var Generator
  • 380V Rack Mount Static Var Generator380V Rack Mount Static Var Generator
  • 380V Rack Mount Static Var Generator380V Rack Mount Static Var Generator
  • 380V Rack Mount Static Var Generator380V Rack Mount Static Var Generator
  • 380V Rack Mount Static Var Generator380V Rack Mount Static Var Generator

380V Rack Mount Static Var Generator

The 380V Rack Mount Static Var Generator is a powerful solution for maintaining voltage stability and improving power factor in high-demand environments. If you're looking for reliable performance and efficiency, request a quote today! Our expert team is ready to provide tailored solutions to meet your specific needs. With our cutting-edge technology, you can enhance energy efficiency and ensure consistent power quality.

The 380V Rack Mount Static Var Generator (SVG) offers dynamic reactive power compensation for three-phase 380V electrical systems. This SVG utilises advanced DSP+CPLD digital control and a three-level topology, ensuring precise and responsive compensation with a full response time under 10ms. Designed for convenient installation in standard 19-inch racks, the rack mount configuration saves space and simplifies maintenance. Available capacities range from 15kvar to 100kvar (15kvar, 35kvar, 50kvar, 75kvar, and 100kvar), allowing for flexible application in diverse industrial settings.

Model description:

GY SVG 0.4 50K / 4L R
Enterprise code Static var generator Voltage level
0.4:380V±20%
Rated Capacity (kvar) 10/15/35/50/75/100kvar 3L:Three-phase three-wire
4L:Three-phase four-wire
R:Rack mount

Features:

● Use DSP+CPLD all digital control core, three-level topology technology, advanced reactive power detection algorithm and PWM control strategy to achieve dynamic and accurate compensation of reactive power.
● Adopt modular design, which facilitates parallel connection of multiple modules, takes small space and is easy to maintain.
● The structural design of independent air ducts and independent warehouses ensures the stable operation of the equipment.
● Carry out full-range dynamic compensation for inductive reactive power and capacitive reactive power, and solve the three-phase unbalance problem at the same time.
● The dynamic response speed to the load is at the millisecond level, which can achieve dynamic and accurate compensation for the reactive power of impact loads.

Applications:

380V Rack Mount Static Var Generators are ideal for industrial applications demanding effective reactive power control in three-phase 380V systems:

Industrial Motor Control (Three-Phase): Improving the efficiency and power factor of three-phase motors, reducing energy consumption and operating costs.
Power Factor Correction (Industrial): Correcting power factor in industrial facilities, minimising electricity costs and enhancing the capacity of existing electrical infrastructure.
Harmonic Mitigation (Three-Phase Systems): Reducing harmonic distortion in three-phase systems, protecting sensitive equipment and improving power quality.
Renewable Energy Integration (Three-Phase): Facilitating seamless integration of three-phase renewable energy sources, ensuring grid stability and maintaining high power quality.

380V Rack Mount Static Var Generators deliver a robust and efficient solution for optimising power quality and efficiency in demanding industrial environments.

380V Rack Mount Static Var Generator

Technical Parameters:

220V series 380V series 500V series 690V series
Altitude < 2000m, above 2000m, derate according to GB/T3859.2
Ambient temperature -20~+50℃
Relative humidity ≤90%, no condensation on the surface when the monthly minimum temperature is 25℃
Pollution level Level III below
Operating Voltage AC220V±20% AC380V±20% AC500V±20% AC690V±20%
Working frequency 50Hz±5%
Rated compensation capacity 5kvar 15/35/50/75/100kvar 90kvar 120kvar
Grid structure L/N 3P3W/3P4W
Number of units connected in parallel Ulimited
Overall machine efficiency ≥97%
On-off frequency 32kHz 16kHz 12.8kHz 12.8kHz
Function selection Reactive power Reactive po wer、Reactive po wer+imbalance
Reactive power compensation rate ≥99%  >95%
Full response time  <10ms 
Noise ≤60dB ≤60dB ≤65dB ≤65dB
Control method 2-way RS485 interface (supports GPRS/WIFI)
Protection Overload, software/hardware overcurrent, grid overvoltage and undervoltage, power failure, overtemperature, frequency abnormality protection, etc. Overload, software/hardware overcurrent, grid overvoltage and undervoltage, grid voltage imbalance, power failure, overtemperature, frequency abnormality, shot circuit protection, etc.
Installation method Rack/wall-mounted Rack
Incoming line Back incoming(rack type)、 upper incoming(wall-mounted) Back incoming line
Protection level IP20

Model& Specification:

380V Rack Mount Static Var Generator

Models
Model Number Compensation capacity (kvar) System voltage (V) Dimensions (D*W*H) Cooling method
GY SVG-0.22-5k/2L-R/W 5 220 220*330*160mm Forced air cooling
GY SVG-0.4-15k/4L-R/W 15 380±20% 460*490*89mm
GY SVG-0.4-35k/4L-R/W 35 380±20% 460*490*89mm
GY SVG-0.4-50k/4L-R/W 50 380±20% 500*510*190mm
GY SVG-0.4-75k/4L-R/W 75 380±20% 500*550*240mm
GY SVG-0.4-100k/4L-R/W 100 380±20% 500*550*240mm
GY SVG-0.5-90k/4L-R/W 90 500±20% 495*675*275mm
GY SVG-0.69-120k/4L-R/W 120 690±20% 495*675*275mm
Hot Tags: 380V Rack Mount Static Var Generator
Send Inquiry
Contact Info
For inquiries about active harmonic filter, static var generator, power quality or price list, please leave your email to us and we will be in touch within 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept